Flexstar Available

Flexstar Zeus X2 Smart Controller

Two-channel lighting control with spectrum, UV and far-red schedules, and a live room readout.

The Flexstar Zeus X2 Smart Controller (model X2A) runs two independent channels of Flexstar LED or HID fixtures — up to 100 per channel over RS-485 — with dimming, spectrum, sunrise/sunset and separate UV and far-red schedules, while showing temperature, humidity, VPD and CO₂ on the same screen.

2 Channels
Independent Light Control
100 / Channel
Fixtures (RS-485); 80 on 0-10V
Main · UV · FR
Light Types per Channel
Temp · RH · VPD · CO₂
Room Readout

What the Zeus X2 Controls

The Zeus X2 is Flexstar's wall-mounted controller for its LED and HID fixtures. It has two lighting channels, each with its own RJ11 light-control port and sensor port. A channel drives up to 100 fixtures over RS-485 or 80 fixtures over 0-10V, and dims them in steps of OFF, 25, 40, 50, 60, 80 and 100%.

Each channel carries three light types — main, UV and far-red — and each type runs in manual mode or on a daily schedule. UV and far-red each take a second daily schedule, so a supplemental window can run twice a day without a second timer.

Channel 2 can run on its own program or follow Channel 1, so two rooms can share one controller or two halves of one room can run the same recipe.

Spectrum, Sunrise and Sunset

On Flexstar fixtures built for spectral tuning, the X2 sets the main-light spectrum by stage — the screen labels them Seedling, Veg, Early Flower and Late Flower. Fixtures without spectral tuning ignore the setting and dim normally.

With sunrise/sunset turned on, lights ramp up to the set level, and back down to off, over 10 minutes at each on and off time instead of switching hard.

Room Readout and Heat Protection

The included temperature/humidity sensor (7 m cable) feeds the screen with temperature, humidity and VPD; add the optional CO₂ sensor for a CO₂ reading (10–5,000 ppm). Each channel reads its own sensor, and readings can be calibrated from the controller.

Auto dim drops the main lights to 50% of their setting when that channel's temperature reaches the trigger you set (86–194°F), and holds until the room is 0.9°F below the trigger for 30 seconds. Auto shutdown turns the main lights off at a higher trigger and needs a manual reset. Flexstar recommends setting the trigger at least 3.6°F above your HVAC setpoint.

Installation

The X2 measures 5.43 × 3.33 × 1.04 in and weighs 0.48 lb. It mounts with 3M adhesive, on two screws through its slotted hanging holes, or magnetically on the included iron plate. A 100–240V AC adapter supplies 12V DC. The screen can be locked to stop accidental changes on the floor.

Wiring & Ports

Zeus X2 system wiring diagram
Each channel runs its own lights and sensor. CO₂ sensor and splitters sold separately.
Zeus X2 port layout
RJ11 light control and sensor ports for Channels 1 and 2, 12V DC input and reset.

Specifications

ModelZeus X2 (X2A)
Lighting Control Channels2 (independent, or Channel 2 follows Channel 1)
Fixtures per Channel100 (RS-485); 80 (0-10V)
Dimming LevelsOFF / 25% / 40% / 50% / 60% / 80% / 100%
Light TypesMain, UV, far-red — manual or schedule each
Spectrum StagesSeedling, Veg, Early Flower, Late Flower (spectral-tuning fixtures)
Sunrise / Sunset10-minute ramp at on and off
SensorsTemperature/humidity (included, 7 m); CO₂ (sold separately)
Temperature-4 to 176°F (-20 to 80°C), ±0.2°C
Humidity0–100% RH, ±2%
CO₂10–5,000 ppm, ±(50 ppm + 3% F.S.)
Auto Dim / Auto ShutdownMain lights; dim to 50% at trigger temp (86–194°F); shutdown needs manual reset
PortsRJ11 light control ×2, RJ11 sensor ×2, 12V DC, reset
PowerAdapter 100–240V AC, 50/60 Hz, 0.2 A; controller 12V DC, 1 A
Operating Environment32–122°F (0–50°C), ≤80% RH
Dimensions5.43 × 3.33 × 1.04 in (138 × 86.5 × 26.5 mm)
Weight0.48 lb
MountingScrews, magnet (iron plate included) or 3M adhesive
In the BoxController, iron plate, 2 expansion screws, 2 RJ11 6P6C cables (3 m), temp/humidity sensor (7 m), power adapter, cable ties

Frequently Asked Questions

How many lights can one Zeus X2 run?

Up to 100 Flexstar fixtures per channel over RS-485, or 80 per channel over 0-10V — two channels per controller.

Does the X2 come with a CO₂ sensor?

No. It ships with a temperature/humidity sensor on a 7 m cable; the CO₂ sensor is sold separately.

Can the X2 control lights from other brands?

Flexstar specifies the X2 for compatible Flexstar LED and HID lights only and warns against connecting other products.

What happens if the room overheats?

If auto dim is on, the main lights drop to 50% of their setting when the channel's temperature reaches your trigger. If auto shutdown is on, they turn off at the shutdown trigger and stay off until reset manually.

Can UV and far-red run on their own schedules?

Yes. UV and far-red each run in manual or schedule mode, with up to two on/off windows per day, separate from the main lights.

Ready to spec this for your facility?

Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.

Request a Quote